'''Power supply:''' The converter requires power from two different sources. The higher voltage (from 1.7 V to 5.5 V) should be connected to the pin marked as VCC_B, and the lower voltage (from 1. | '''Power supply:''' The converter requires power from two different sources. The higher voltage (from 1.7 V to 5.5 V) should be connected to the pin marked as VCC_B, and the lower voltage (from 1.2 V to 3.6 V) should be connected to VCC_A.<br> | ||
'''Ground:''' Both devices and the converter must have a common ground, so the ground wire should be connected to the pin marked as GND.<br> | '''Ground:''' Both devices and the converter must have a common ground, so the ground wire should be connected to the pin marked as GND.<br> | ||
'''Logical signals:''' Signals should be connected to the appropriate connectors. Signals with a higher voltage should be connected to the Bx connectors, and signals with a lower voltage to the Ax connectors. <center> | '''Logical signals:''' Signals should be connected to the appropriate connectors. Signals with a higher voltage should be connected to the Bx connectors, and signals with a lower voltage to the Ax connectors. <center> | ||
[[File: | [[File:KAmodTXS0108_conn_EN.png|none|1200px|thumb|center]] | ||
</center> | </center> | ||
<br><br> | |||
===== Dimensions ===== | ===== Dimensions ===== | ||
Line 49: | Line 50: | ||
</center> | </center> | ||
<br><br> | |||
===== External links ===== | ===== External links ===== | ||
*[https://wiki.kamamilabs.com/images/e/e0/Txs0108e.pdf Texas Instruments TXS108EPW | *[https://download.kamami.pl/p581753-txs0108%20zastosowania.pdf TXS0108 Guide and Applications] | ||
*[https://wiki.kamamilabs.com/images/e/e0/Txs0108e.pdf Texas Instruments TXS108EPW Datasheet] |
Latest revision as of 16:15, 1 March 2025

Description
KAmodTXS0108 is a module with the TXS0108 system from Texas Instruments. The system is an 8-channel voltage translator. Thanks to the built-in direction detection system, the module provides two-way signal flow without the need to use an additional pin. Thanks to its small dimensions, the product can be used in many development projects.

Basic Features
- Texas Instruments TXS0108E
- 8 Channels
- Level Shift: Bidirectional
- Power Supply:
- VCCA from 1.2 V to +3.6 V,
- VCCB from 1.7 V to +5.5 V,
- VCCA < VCCB
- Dimensions: 16 x 29 mm
Standard Equipment
Code | Description |
---|---|
KAmodTXS0108 |
|
Schematic

Connection
Power supply: The converter requires power from two different sources. The higher voltage (from 1.7 V to 5.5 V) should be connected to the pin marked as VCC_B, and the lower voltage (from 1.2 V to 3.6 V) should be connected to VCC_A.
Ground: Both devices and the converter must have a common ground, so the ground wire should be connected to the pin marked as GND.
Logical signals: Signals should be connected to the appropriate connectors. Signals with a higher voltage should be connected to the Bx connectors, and signals with a lower voltage to the Ax connectors.

Dimensions